DeVilbiss PROV-650 visor complete air fed mask waist belt.


Complete air fed full face respiratory protection. The gun supply hose swivels both radially and laterally which ensures better spray dynamics without the hose restricting the movement of the sprayer. The Pro Visor disperses breathing air gently and evenly around the lightweight visor with no misting or discomfort. This ensures every sprayer can work in comfort and reassurance.

The wrap around the visor provides excellent and much wider peripheral vision than previous and other air fed masks. The removable peak can help reduce glare from spray booth lighting. A whistle is incorporated to warn the sprayer that an insufficient quantity of breathing air is being supplied to the mask.

Gun supply hose swivels both radially and literally, ensuring better spray dynamics with out hose restricting the movement of the sprayer. Left or right sided waist belt fitment without having to change the air fitting configuration.

 


The Pro Visor disperses breathing air gently around the lightweight visor at a positive pressure with no misting or discomfort, ensuring every sprayer can work at their best.
The wrap around visor provides excellent and much wider peripheral vision than sprayers will be used to, while the removable peak can help reduce glare from spray booth lighting.

A whistle is incorporated to warn the operator that an insufficient quantity of breathing air is being supplied to the Pro-Visor. Should the whistle sound during use, the operator should vacate the spraying area immediately with the unit still on and check the air supply, i.e. look for crushed or cut supply hose. Each time the Pro-Visor is used the device should be checked in a safe area, to do this the headpiece should be worn as normal and the air supply reduced to approximately 1 bar or less, this will cause the whistle to sound, when the pressure is restored to a safe level the whistle silences.

Technical Specifications

Protection: APF=40 / NPF=200
Carbon filter life: 3 months
Supply pressure: 4.0 bar (60psi) minimum to 7.0 bar (100psi) maximum
Air flow rate: 160 - 220 L/min (5.7 - 7.8 scfm)
Noise level @ 200 L/min: 80 dB (A)
Approvals: PPE directive 89/686/EEC. Conforms to EN 14594:2005 Class 3A
Zone classifications: Suitable for use in Zones 1 and 2 hazardous areas (gas groups llA)

It is essential that all breathing air supplied to an air fed mask must be passed through a 2 or 3 stage filter to remove oil vapour and other impurities from the compressed air.


DeVilbiss PROV-650 visor complete air fed mask waist belt.


Complete air fed full face respiratory protection. The gun supply hose swivels both radially and laterally which ensures better spray dynamics without the hose restricting the movement of the sprayer. The Pro Visor disperses breathing air gently and evenly around the lightweight visor with no misting or discomfort. This ensures every sprayer can work in comfort and reassurance.

The wrap around the visor provides excellent and much wider peripheral vision than previous and other air fed masks. The removable peak can help reduce glare from spray booth lighting. A whistle is incorporated to warn the sprayer that an insufficient quantity of breathing air is being supplied to the mask.

Gun supply hose swivels both radially and literally, ensuring better spray dynamics with out hose restricting the movement of the sprayer. Left or right sided waist belt fitment without having to change the air fitting configuration.

 


The Pro Visor disperses breathing air gently around the lightweight visor at a positive pressure with no misting or discomfort, ensuring every sprayer can work at their best.
The wrap around visor provides excellent and much wider peripheral vision than sprayers will be used to, while the removable peak can help reduce glare from spray booth lighting.

A whistle is incorporated to warn the operator that an insufficient quantity of breathing air is being supplied to the Pro-Visor. Should the whistle sound during use, the operator should vacate the spraying area immediately with the unit still on and check the air supply, i.e. look for crushed or cut supply hose. Each time the Pro-Visor is used the device should be checked in a safe area, to do this the headpiece should be worn as normal and the air supply reduced to approximately 1 bar or less, this will cause the whistle to sound, when the pressure is restored to a safe level the whistle silences.

Technical Specifications

Protection: APF=40 / NPF=200
Carbon filter life: 3 months
Supply pressure: 4.0 bar (60psi) minimum to 7.0 bar (100psi) maximum
Air flow rate: 160 - 220 L/min (5.7 - 7.8 scfm)
Noise level @ 200 L/min: 80 dB (A)
Approvals: PPE directive 89/686/EEC. Conforms to EN 14594:2005 Class 3A
Zone classifications: Suitable for use in Zones 1 and 2 hazardous areas (gas groups llA)

It is essential that all breathing air supplied to an air fed mask must be passed through a 2 or 3 stage filter to remove oil vapour and other impurities from the compressed air.

All goods are supplied with a manufacturers twelve month warranty, (or longer in some cases), provided the goods are used in accordance with the manufacturer's instructions. This warranty does not apply to any defect which arises from general wear and tear, losses caused by loss of use of the goods, wilful or accidental damage, or negligence by you or any third party. The cost of returning goods for repair/replacement is the responsibility of the owner, we may request that the item is returned direct to the manufacturer for repair/replacement - if so we will liaise between both parties.